Page 18 - B+D Catalogue
P. 18

18       4. RESPIRATORY PROTECTION




            FACE MASKS
            BXFM1002IN


             IS 9473:2002
             CM/L-8300137209
            l Comfortable ear loops.
            l Inbuilt metal-reinforced flexible plastic nose clip.
            l Ear loops with Ultrasonic sealing for better strength.
            l Specially designed for full face coverage, exerting uniform
             pressure over user's face.
            l Highly breathable.
            l Also Available in White Color.



                                                                                                     NEW










            FACE MASKS
            BXFM1012IN


             IS 9473:2002
             CM/L-8300137209
            l Comfortable and adjustable headbands.
            l Inbuilt metal-reinforced flexible plastic nose clip.
            l Headbands with Ultrasonic sealing for better strength.
            l Specially designed for full face coverage, exerting uniform
             pressure over user's face.
            l Highly breathable.
            l Comes with a comfortable nose pad.
            l Also Available in White Color.
                                                                                                     NEW









            Vital Test                 Requirement as per IS 9473:2002 Standard  BXFM1002IN and BXFM1012IN

                                                                                Particulate Filtering Efficiency  for Nacl
                                       Minimum Particulate Filtering Efficiency
            Particulate Filtering Efficiency   should be 94% for Nacl Aerosol and should   Aerosol- Greater than -95%
            (Clause 5.4.2 of IS 9473:2002)                                      Particulate Filtering Efficiency  for Paraffin Oil
                                       be 98% for Paraffin Oil Aerosol.
                                                                                Aerosol- Greater than -98%
                                       Maximum Permitted Inhalation Resistance at   Inhalation Resistance at 30L/Min- Less than
                                       30L/Min -0.7 mbar.                       0.6 mbar
            Breathing Resistance       Maximum Permitted Inhalation Resistance at   Inhalation Resistance at 95L/Min- Less than -
            (Clause 5.11 of IS 9473:2002)  95 L/min -2.4 mbar.                  2.0 mbar
                                       Maximum Permitted Exhalation Resistance at   Exhalation Resistance at 160L/Min-Less than
                                       160 L/min-3.0 mbar.                      2.2mbar
                                       The Maximum Total Inward Leakage of 46   The Maximum Total Inward Leakage of 46
                                       Exercises out of 50 Exercises is should not be   Exercises out of 50 Exercises less than 8%
            Total Inward Leakage       more than 11%
            (Clause 5.4.1 of IS 9473:2002)  at least 8 out of 10 individual wearer   Arithmetic Mean of all 10 Individual wearer
                                       arithmetic means for the total inward leakage   Total Inward leakage is less than 6%
                                       shall not be greater than 8%